Distribution Transformer
Distribution Transformer

Distribution Transformer

MOQ : 1 Unit

Distribution Transformer Specification

  • Coil Material
  • Copper
  • Voltage Booster Type
  • Step Down
  • Rated Voltage
  • 11 kV / 0.415 kV
  • Dimension (L*W*H)
  • 1800 x 800 x 1200 mm
  • Capacity
  • 100 kVA - 2000 kVA
  • Cooling Type
  • ONAN (Oil Natural Air Natural)
  • Low Voltage
  • 415 V
  • Operating Temperature
  • -25C to +50C
  • Standard
  • IS 1180, IEC 60076
  • High Voltage
  • 11 kV
  • Load Loss
  • Less than 1200 W
  • Product Type
  • Distribution Transformer
  • Material
  • Copper and Silicon Steel
  • Output
  • AC
  • Frequency (MHz)
  • 50 Hz
  • Efficiency
  • 98%
  • Phase
  • Three Phase
  • Usage
  • Power Distribution
  • Coil Structure
  • Laminate
  • Coil Number
  • 2 (Primary and Secondary)
  • Power Scope
  • Up to 2000 kVA
  • Weight
  • Approximately 1000 kg
  • Protection
  • Buchholz Relay, Overpressure Relief Device
  • Impedance Voltage
  • 4.5% - 8%
  • Mounting Type
  • Pad Mounted
  • Tap Changer
  • Off Circuit Tap Changer
  • Oil Volume
  • 120 Litres
  • Cooling Medium
  • Mineral Oil
  • Winding Type
  • Disc and Layer Winding
  • Terminals
  • Copper Busbar
  • Noise Level
  • Less than 55 dB
  • Insulation Class
  • Class A/B
  • Painting
  • Epoxy Powder Coated
 

Distribution Transformer Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 2-5 Days
  • Main Domestic Market
  • All India
 

More Products in Power Segment Category

Power Transformer

Power Transformer

Minimum Order Quantity : 1 Unit

Power Scope : 25 kVA to 2500 kVA

Coil Material : Other , Electrolytic Copper or Aluminum

Weight : 800 kg to 3500 kg depending on rating

Frequency (MHz) : 50 Hz (0.05 MHz)

Efficiency : Up to 98%

Step UP And Down Transformer

Step UP And Down Transformer

Minimum Order Quantity : 1 Unit

Power Scope : 1 KVA to 1000 KVA

Coil Material : Other , Copper/Aluminum

Weight : Depends on KVA rating, typically 25kg to 950kg

Frequency (MHz) : 50/60 Hz

Efficiency : Up to 98%

Furnace Transformer

Furnace Transformer

Minimum Order Quantity : 1 Unit

Power Scope : Up to 30 MVA or as required

Coil Material : Other , Copper or Aluminum

Weight : 10,000 kg (approx., varies with rating)

Frequency (MHz) : 50 Hz / 60 Hz

Efficiency : Up to 98%

Isolation Transformer

Isolation Transformer

Minimum Order Quantity : 1 Unit

Power Scope : Up to 200 kVA

Coil Material : Other , High Grade Copper

Weight : Varies with Capacity (Example: 80 kg for 10 kVA)

Frequency (MHz) : 50/60 Hz

Efficiency : 98%



Back to top